Skip to main content

Configure a Custom Insight

As described in the Insight Generation Process topic, Cloud SIEM automatically generates an Insight based on an Entity’s Activity Score, which is the cumulative severity of the unique Signals that have fired on an Entity during a period of time. In some cases, you may want Cloud SIEM to generate an Insight on some basis other than Entity Activity Scores. For example, you might want an Insight generated whenever a particular set of Signals are fired in a particular order. 

This topic has instructions for defining a Custom Insight, which is a configuration you set up that causes Cloud SIEM to generate Insights based purely on one or more Signals being fired.

Ways to define a Custom Insight

There are two ways you can define a Custom Insight. You can specify that the Insight should be generated each time:

  • One or more selected rules fire a Signal.
  • Signals whose name matches a specified wildcard expression are fired. 

Which method should you use? The difference is whether you’re going to create an Insight based on the name of the rule that fired the Signal, or based on the name of the Signal that was fired. Typically, Signals that a rule generates have the same name as the rule. That is not the case with Cloud SIEM’s normalized rules. That’s because normalized rules, for example Normalized Threat rules, are written to work with multiple data sources. The names of the Signals that a normalized rule fires vary by data source. So, if you want your Custom Insight configuration to generate Insights for Signals fired by normalized rules, you should base it on Signal names, rather than rule names.

When the conditions of a Custom Insight configuration are met during the currently configured detection window, an Insight will be generated for each Entity involved. In other words, if each of the Signals in a Custom Insight configuration fired on a different Entity, an Insight will be created on each of those Entities. The generated Insights will include not only the Signals that it fired on, but also any related Signals.

This example Custom Insight configuration will generate an Insight as a result of the Mimecast - Message with Virus Detections from IP rule firing a Signal. 

Custom Insight example

 

Create a Custom Insight

To create a Custom Insight:

  1. Choose Custom Insights on the Content menu.
  2. Click Create on the Custom Insights page.
    Custom Insights page
  3. The Configure the Custom Insight popup appears.
    Configure an Insight
  4. In the Name field, enter a name for the Custom Insight.
  5. If you want the Custom Insight to be generated based on one or more rules firing Signals, jump to step 6, below. Otherwise: 
    1. Leave the When Signals are created from the following... clause set to Signal names.
    2. Enter an expression that matches the name(s) of the Signals of interest. For example: Critical Severity Intrusion Signature *
    3. Click Add.
    4. If you want to, you can enter one or more additional Signal expressions.
    5. If you’ve configured more than one Signal expression, use the in ... order clause to specify whether the Signals must occur in exact order, or whether the Signals can occur in any order. 
  6. If you want the Custom Insight to be generated based on one or more rules firing Signals:
    1. Change the When Signals are created from the following... clause to rule
    2. In the Type to add a Rule area, enter a string that the ID of the desired rule contains.
    3. In the list of rules that appears, scroll to the desired rule and click it.
    4. If you want to, you can search for and select one or more additional rules.
    5. If you’ve configured more than one rule, use the in ... order clause to specify whether the rules must fire Signals in exact order, or in any order. 
  7. In the Then Create an Insight section on the right side of the popup, enter a name for the Insight.
  8. Enter a description of the Insight, as desired.
  9. For severity, you can choose between a constant severity, or a dynamic severity that is based on the severity of the Signals that trigger the Insight. If you want to configure dynamic severity, skip to the next step. To configure constant severity, select one of: Low, Medium, High, or Critical. 
  10. To configure dynamic severity for the custom Insight:
    1. Choose dynamic severity.
    note

    You can define dynamic severity for record fields on Match rules and Aggregation rules.

    1. Select a default severity, one of Low, Medium, High, or Critical
    2. Minimum Signal Severity and Insight Severity. Enter a minimum Signal severity and associated Insight severity value. For example, if you enter 8 and select high, if any Signal in the Insight has a severity of 8 or higher, the custom Insight will have High severity. 
    3. If desired, you can enter a minimum Signal severity value for other Insight severity levels. For example, you could configure a minimum Signal severity of 4 as the threshold for an Insight severity level of Medium. If you do define multiple thresholds, we honor them from highest to lowest. For example, with the following configuration:
      • If the highest Signal severity was at least 7, severity is Critical.
      • If the highest Signal severity was at least 5, severity is Medium.
      • If the highest signal severity was at least 3, severity is Low.
        Example dynamic severity
  11. If desired, select Tags that you want assigned to the Custom Insight. 
  12. Click Submit to save your Custom Insight configuration.
Status
Legal
Privacy Statement
Terms of Use

Copyright © 2024 by Sumo Logic, Inc.