Skip to main content

Collect Logs

The Sumo Logic Distribution for OpenTelemetry Collector provides various receivers for log collection. This document describes the most common scenarios.

You can find the full list of receivers on our Sumo Logic OpenTelemetry Collector page.

Additional information

See Additional Configurations Reference for more details about configuring the Sumo Logic OpenTelemetry Collector.

Collecting logs from local files​

Following configuration demonstrates:

  • Collect: How to collect logs stored in /var/log/syslog and /var/log/audit/audit.log.

  • Transform: Set _sourceCategory field to application_logs_prod

  • Export: Send data to authenticated Sumo Logic organization.

    receivers:
    filelog/custom_files:
    include:
    - /var/log/syslog
    - /var/log/audit/audit.log
    include_file_name: false
    include_file_path_resolved: true
    storage: file_storage

    processors:
    groupbyattrs/custom_files:
    keys:
    - log.file.path_resolved
    resource/custom_files:
    attributes:
    - key: _sourceCategory
    value: application_logs_prod
    action: insert
    - key: sumo.datasource
    value: linux
    action: insert
    sumologic_schema/custom_files:

    service:
    pipelines:
    logs/custom_files:
    receivers:
    - filelog/custom_files
    processors:
    - memory_limiter
    - groupbyattrs/custom_files
    - resource/custom_files
    - resourcedetection/system
    - sumologic_schema/custom_files
    - batch
    exporters:
    - sumologic
  1. Create a file in folder /etc/otelcol-sumo/conf.d with name for your choice, perhaps matching the pipeline name, custom_files.yaml. Its name has to end with .yaml.
  2. Paste the above content.
  3. Restart collector with following command:
    Linux
    systemctl restart otelcol-sumo
    Windows
    Restart-Service -Name OtelcolSumo

Configuration details:

  • receivers:

    • filelog/custom_files: Unique name defined for the filelog receiver. You can add multiple filelog receivers as filelog/2, filelog/prod etc.
      • include Lets the Filelog receiver know where the log files are placed. Make sure that the collector has permissions to read the files; otherwise, the logs will not be collected.
      • include_file_path_resolved: true Adds a log.file.path_resolved attribute to the logs that contain the whole path of the file.
      • storage: file_storage Prevents the receiver from reading the same data over and over again on each otelcol restart. The file_storage extension is defined in the default /etc/otelcol-sumo/sumologic.yaml file.
  • processors:

    • groupbyattrs/custom_files Moves the log.file.path_resolved attribute from log record level to resource level to reduce data duplication.
    • resource/custom_files Adds the _sourceCategory resource attribute with value application_logs_prod.
    • sumologic_schema/custom_files Translates attributes to names understood by Sumo Logic apps, for example renames the resource attribute log.file.path_resolved to _sourceName.
  • exporters:

    • sumologic Sends data to the registered Sumo Logic organization. This exporter is preconfigured in the sumologic.yaml file during installation.
  • service.pipelines:

    • logs/custom_files: Pipeline glues together the receivers with the processors and the exporters.

The remaining processors in pipeline are defined in the sumologic.yaml file and should be applied for better performance of the collector.

note

The names of the components defined in this file (filelog/custom_files, groupbyattrs/custom_files, resource/custom_files) and the pipeline name (logs/custom_files) should be unique across all configuration files to avoid conflicts and unexpected behavior.

For more details, see the Filelog receiver documentation.

Parsing JSON logs​

Use Filelog receiver with json_parser operator to parse JSON logs.

For example, given the following file where each line is a JSON message:

{"timestamp": "2022-01-01T12:23:34Z","message": "User logged in successfully","severity": "INFO","user_id": 1234}
{"timestamp": "2022-01-01T15:34:21Z","message": "Error processing request","severity": "ERROR","error_code": 500,"error_message": "Internal Server Error","request_id": "ABC123"}

Then configuration has following form:

receivers:
filelog/json_files:
include:
- /var/log/myservice/*.log
include_file_name: false
include_file_path_resolved: true
storage: file_storage
operators:
- type: json_parser
parse_to: body

processors:
groupbyattrs/json_files:
keys:
- log.file.path_resolved
resource/json_files:
attributes:
- key: sumo.datasource
value: linux
action: insert
sumologic_schema/json_files:

service:
pipelines:
logs/json_files:
receivers:
- filelog/json_files
processors:
- memory_limiter
- groupbyattrs/json_files
- resource/json_files
- resourcedetection/system
- sumologic_schema/json_files
- batch
exporters:
- sumologic

Collecting logs from Windows Event Log​

Windows Log Event Receiver reads and parses logs from windows event log API to collect local events as you see on Windows Event Viewer.

Collecting Application, Security and System channels​

Following configuration demonstrates:

  • Collect: Collect Application, Security and System channels.

  • Transform: Set _sourceCategory field to windows_event_log_prod.

  • Export: Send data to authenticated Sumo Logic organization.

    receivers:
    windowseventlog/application/localhost:
    channel: Application
    windowseventlog/security/localhost:
    channel: Security
    windowseventlog/system/localhost:
    channel: System

    processors:
    resource/windows_resource_attributes/localhost:
    attributes:
    - key: _sourceCategory
    value: windows_event_log_prod
    action: insert
    - key: sumo.datasource
    value: windows
    action: insert

    service:
    pipelines:
    logs/windows/localhost:
    receivers:
    - windowseventlog/application/localhost
    - windowseventlog/system/localhost
    - windowseventlog/security/localhost
    processors:
    - memory_limiter
    - resource/windows_resource_attributes/localhost
    - batch
    exporters:
    - sumologic
  1. Create a file in folder C:\ProgramData\Sumo Logic\OpenTelemetry Collector\config\ with name sample_windows.yaml.
  2. Paste the above content into the file.
  3. Restart collector with following command:
    Windows
    Restart-Service -Name OtelcolSumo

Configuration details:

  • receivers:

    • windowseventlog/application/localhost: Collect logs from application channel.
    • windowseventlog/security/localhost: Collect logs from security channel.
    • windowseventlog/system/localhost: Collect logs from system channel.
  • processors:

    • resource/windows_resource_attributes/localhost Adds the resource attribute _sourceCategory with value windows_event_log_prod
  • exporters:

    • sumologic Sends data to the registered Sumo Logic organization. This exporter is preconfigured in the sumologic.yaml file during installation.
  • service:

    • logs/custom_files: Pipeline glues together the receivers with the processors and the exporters.

Collect from Custom channels (Powershell, Sysmon)​

Following configuration demonstrates:

  • Collect: Collect Sysmon logs.
  • Transform: Set _sourceCategory field to windows_event_log_prod_sysmon.
  • Export: Send data to authenticated Sumo Logic organization.
receivers:
windowseventlog/sysmon/localhost/1690233479:
channel: Microsoft-Windows-Sysmon/Operational

processors:
resource/windows_resource_attributes/localhost/1690233479:
attributes:
- key: _sourceCategory
value: windows_event_log_prod_sysmon
action: insert
- key: sumo.datasource
value: windows
action: insert

service:
pipelines:
logs/windows/localhost/1690233479:
receivers:
- windowseventlog/sysmon/localhost/1690233479
processors:
- memory_limiter
- resource/windows_resource_attributes/localhost/1690233479
- batch
exporters:
- sumologic
  1. Create a file in folder C:\ProgramData\Sumo Logic\OpenTelemetry Collector\config\ with name sysmon_windows.yaml.
  2. Paste the above content into the file.
  3. Restart collector with following command:
    Windows
    Restart-Service -Name OtelcolSumo

Configuration details​

  • receivers: windowseventlog/sysmon/localhost/1690233479: Collect logs from sysmon channel with name β€œMicrosoft-Windows-Sysmon/Operational”.
  • processors: resource/windows_resource_attributes/localhost/1690233479 Adds the resource attribute _sourceCategory with value windows_event_log_prod_sysmon
  • exporters: sumologic Sends data to the registered Sumo Logic organization. This exporter is preconfigured in the sumologic.yaml file during installation.
  • service: logs/custom_files: Pipeline glues together the receivers with the processors and the exporters.

For more details, see the Windows Event Log receiver.

Collecting logs from Syslog​

The OpenTelemetry Collector offers two approaches for Syslog processing:

The following table shows the comparison of these components.

Feature/CapabilityOpenTelemetry Syslog ReceiverTCPlog/UDPlog Receiver and Sumo Logic Syslog Processor
RecommendationParse syslog into structured logsCompatibility with the current Installed Collector behavior is needed
Network protocolTCP, UDPTCP, UDP
Syslog formatRFC3164 and RFC5424 formatsAny format
Field ParsingCollector sideNot on collector side
Protocol VerificationStrict parsing; logs sent to the wrong endpoint will not be parsedNo protocol verification; all formats are treated the same

Parsing Syslog logs into structured logs​

Following configuration demonstrates:

  • Collect: Collect syslog sent using UDP protocol to 172.31.93.11 on port 5140
  • Transform: Set _sourceCategory field to syslog_event_log_prod
  • Export: Send data to authenticated Sumo Logic organization
receivers:
syslog/local_syslog:
udp:
listen_address: "172.31.93.11:5140"
protocol: rfc5424

processors:
resource/local_syslog:
attributes:
- key: _sourceCategory
value: syslog_event_log_prod
action: insert
- key: sumo.datasource
value: linux
action: insert

service:
pipelines:
logs/local_syslog:
receivers:
- syslog/local_syslog
processors:
- resource/local_syslog
exporters:
- sumologic
  1. Create a file in folder /etc/otelcol-sumo/conf.d with name for your choice, e.g. local_syslog.yaml.
  2. Paste the above content to local_syslog.yaml
  3. Restart collector with following command:
    Linux
    systemctl restart otelcol-sumo
  4. You can validate if the configuration was successful by running the following command:
    Linux
    sudo lsof -i:<port>
    Where port is the port specified in your config above.

For more details, see the Syslog receiver.

Collecting Syslog logs in format compatible with Sumo Logic Installed Collector​

To collect Syslog logs in format compatible with the Sumo Logic Installed Collector, use the TCP Log or UDP Log receiver.

Following configuration demonstrates:

  • Collect: Collect syslog UDP on IP 172.31.93.11 port 5140 and TCP on IP 172.31.93.11 port 1514.
  • Transform: Set _sourceCategory field to syslog_event_log_prod
  • Export: Send data to authenticated Sumo Logic organization
receivers:
tcplog/syslog_plain:
listen_address: "172.31.93.11:1514"
udplog/syslog_plain:
listen_address: "172.31.93.11:5140"

processors:
resource/syslog_plain:
attributes:
- key: _sourceCategory
value: syslog_event_log_prod
action: insert
- key: sumo.datasource
value: linux
action: insert
sumologic_syslog/syslog_plain:

service:
pipelines:
logs/syslog_plain:
receivers:
- tcplog/syslog_plain
- udplog/syslog_plain
processors:
- resource/syslog_plain
- sumologic_syslog/syslog_plain
exporters:
- sumologic
  1. Create a file in folder /etc/otelcol-sumo/conf.d with name for your choice, e.g. tcp_udp_log.yaml.
  2. Paste the above content to tcp_udp_log.yaml
  3. Restart collector with following command:
    Linux
    systemctl restart otelcol-sumo
  4. You can validate if the configuration was successful by running the following command:
    Linux
    sudo lsof -i:<port>
    Where port is the port specified in your config above.

For more details, see the TCP Log or UDP Log receiver.

Collecting logs from SQL databases​

The SQL Query receiver retrieves logs from SQL databases, including MySQL, Oracle and PostgreSQL. See below for configuration for a specific database engine.

note

This section describes the configuration to collect logs stored in DB tables using queries. If you intend to monitor database applications availability, performance, and resource utilization of MySQL database clusters, visit Database Monitoring and find the database of your choice.

Collecting logs from a MySQL database​

Here's an example configuration for MySQL that you can place in the conf.d directory:

receivers:
sqlquery/mysql:
collection_interval: 30s
driver: mysql
datasource: user:password@tcp(host:port)/dbname
storage: file_storage
queries:
- sql: select log_id, log_text from logs_table where log_id > ? order by log_id
tracking_column: log_id
tracking_start_value: 1
logs:
- body_column: log_text
service:
pipelines:
logs/mysql:
receivers:
- sqlquery/mysql
processors:
- memory_limiter
- resourcedetection/system
- batch
exporters:
- sumologic

With this configuration, the SQL Query receiver will run the SQL query select log_id, log_text from logs_table where log_id > ? every 30 seconds and create a log record out of each result row, using the value from the log_text column as the body of the log.

On the first query run, the parameter represented with the question mark ? will be substituted with 1, which is the value of the tracking_start_value property. On subsequent query runs, the last retrieved value of the log_id column from the previous run will be used as the value for the parameter.

The last used tracking value will be stored persistently using the file_storage extension, allowing the collector to pick up where it left off between collector restarts.

Collecting logs from an Oracle database​

Here's an example configuration for Oracle database that you can place in the conf.d directory:

receivers:
sqlquery/oracle:
collection_interval: 30s
driver: oracle
datasource: oracle://user:password@host:port/servicename
storage: file_storage
queries:
- sql: select log_id, log_text from logs_table where log_id > :id order by log_id
tracking_column: LOG_ID
tracking_start_value: 1
logs:
- body_column: LOG_TEXT
service:
pipelines:
logs/oracle:
receivers:
- sqlquery/oracle
processors:
- memory_limiter
- resourcedetection/system
- batch
exporters:
- sumologic

With this configuration, the SQL Query receiver will run the SQL query select log_id, log_text from logs_table where log_id > :id every 30 seconds and create a log record out of each result row, using the value from the log_text column as the body of the log.

On the first query run, the parameter represented with :id will be substituted with 1, which is the value of the tracking_start_value property. On subsequent query runs, the last retrieved value of the log_id column from the previous run will be used as the value for the parameter.

The last used tracking value will be stored persistently using the file_storage extension, allowing the collector to pick up where it left off between collector restarts.

Collecting logs from a PostgreSQL database​

Here's an example configuration for PostgreSQL that you can place in the conf.d directory:

receivers:
sqlquery/postgresql:
collection_interval: 30s
driver: postgres
datasource: "postgresql://user:password@host:port/dbname"
storage: file_storage
queries:
- sql: select log_id, log_text from logs_table where log_id > $$1 order by log_id
tracking_column: log_id
tracking_start_value: 1
logs:
- body_column: log_text
service:
pipelines:
logs/postgresql:
receivers:
- sqlquery/postgresql
processors:
- memory_limiter
- resourcedetection/system
- batch
exporters:
- sumologic

With this configuration, the SQL Query receiver will run the SQL query select log_id, log_text from logs_table where log_id > $1 every 30 seconds and create a log record out of each result row, using the value from the log_text column as the body of the log. Note that you need to escape the dollar character in the YAML config file by adding a second dollar character: $$.

On the first query run, the parameter represented with the dollar one $1 will be substituted with 1, which is the value of the tracking_start_value property. On subsequent query runs, the last retrieved value of the log_id column from the previous run will be used as the value for the parameter.

The last used tracking value will be stored persistently using the file_storage extension, allowing the collector to pick up where it left off between collector restarts.

Troubleshooting the SQL Query receiver​

If you can see the following logs from the collector after applying the configuration:

'' has invalid keys: storage
'queries[0]' has invalid keys: logs, tracking_column, tracking_start_value

Make sure you are using collector version v0.78.0-sumo-0 or higher.

Collecting logs from other sources​

You can find the full list of receivers available on the Sumo Logic OpenTelemetry Collector page. When the Sumo Logic OpenTelemetry Collector does not support collecting logs from a source, the Monitoring Job Receiver (Beta) can be used as a catch-all.

The Monitoring Job Receiver can be configured to execute a script or command on the collector host. The standard output and error streams from that command will be collected as log record(s).

Prefer purpose-built receivers to Monitoring Jobs

When available, prefer purpose-built receivers like sqlquery to monitoring jobs receiver. The below example is about monitoring job configuration that runs SQL queries using the psql tool for demonstration purposes as it is well understood.

This configuration configures the controller to execute the psql command and collects the output text as logs. See the Monitoring Job Receiver documentation for configuration specifics including advanced output processing with features like multi-line log detection, timestamp, and field parsing.

receivers:
monitoringjob/logs_table:
schedule:
interval: 10m
exec:
command: psql
arguments:
- '--csv'
- '-c'
- "select log_id, log_text from logs_table WHERE log_time > (NOW() - interval '10 minutes');"
service:
pipelines:
logs/postgresql:
receivers:
- monitoringjob/logs_table
processors:
- memory_limiter
- resourcedetection/system
- batch
exporters:
- sumologic
Status